Hydraulic System with Counterbalance Valve

This example shows the use of counterbalance valve to balance the load of a double-acting cylinder.

The model consists of a double-acting cylinder controlled by an open-center 4-way directional valve and a power unit built of a flow rate source and a pressure-relief valve. The cylinder is loaded with an active force in 10000 N trying to extend the rod. In other words, the cylinder experiences an overriding load while extending. To hold the rod in place while the directional valve is in neutral position and prevent losing control of the cylinder extension, the counterbalance valve is installed. The valve controls the return flow from port B. The valve pilot port P is connected to cylinder port A, thus making it impossible for the cylinder to move until pressure at port A builds up to certain level.

To hold the load, the counterbalance valve must be set to 1.3 * 10000/ 5e-3 = 26e5 Pa, where 1.3 is the safety coefficient, 10000 N is the load, 5e-5 m^2 is the effective piston area in the rod chamber. The cylinder starts moving as the pilot pressure builds up to approximately p = (p_s � p_L) / (k_p + k_c) , where p_s is the valve setting pressure, p_L is the load pressure (p_L = L/A_r) , L is the load, A_r is the rod chamber effective area, k_p is the pilot ratio (k_p is set to 3 in the model), and k_c is the ratio between the cylinder blank chamber area to the rod chamber area (k_c is set to 2 in the model). As a result, the load starts moving at p = (26e5 � 100000/5e-3) / (3 + 2) = 1.2e5 Pa.

The system is simulated during a 10 s cycle, within which the rod extends by about 0.06 m and then returns to initial position. The pressure plot shows that the counterbalance valve maintains pressure in the rod chamber high enough to balance the load while the directional valve is in neutral position.

Was this topic helpful?