Quantcast

Documentation Center

  • Trial Software
  • Product Updates

X-Y Signal Scope

Plot data from two signals

Library

SimEvents Sinks

Description

The Plot type parameter on the Plotting tab determines whether and how the block connects the points that it plots. For details, see Connections Among Points in Plots.

Ports

Signal Input Ports

LabelDescription
inSignal containing data for Y axis. This signal must be an event-based signal.
xSignal containing data for X axis. This signal must be an event-based signal.

Signal Output Ports

LabelDescription
#cNumber of points the block has plotted.

The initial output value is 0. This value is in effect from the start of the simulation until the first update by the block.

Dialog Box

To open the block dialog box, click the Parameters toolbar button in the plot window.

Plotting Tab

Plot type

The presentation format for the data. See Connections Among Points in Plots for details.

Open scope at start of simulation

Selecting this option causes the plot window to open when you start the simulation. If you clear this box, you can open the plot window by double-clicking the block icon.

Axes Tab

Initial X axis lower limit, Initial X axis upper limit

The interval shown on the X axis at the beginning of the simulation. The interval might change from this initial setting due to zooming, autoscaling, or the If X value is beyond limit setting.

If X value is beyond limit

Determines how the plot changes if one or more X values are not within the limits shown on the X axis. For details, see Vary Axis Limits Automatically.

Initial Y axis lower limit, Initial Y axis upper limit

The interval shown on the Y axis at the beginning of the simulation. The interval might change from this initial setting due to zooming, autoscaling, or the If Y value is beyond limit setting.

If Y value is beyond limit

Determines how the plot changes if one or more Y values are not within the limits shown on the Y axis. For details, see Vary Axis Limits Automatically.

Show grid

Toggles the grid on and off.

Figure Tab

Title

Text that appears as the title of the plot, above the axes.

Y label

Text that appears to the left of the vertical axis.

X label

Text that appears below the horizontal axis.

Figure Position

A four-element vector of the form [left bottom width height] specifying the position of the scope window. (0,0) is the lower left corner of the display.

Show number of points

Displays the number of plotted points using an annotation in the plot window.

Data History Tab

Store data when scope is closed

Select Unlimited to have the block cache all data for future viewing, Limited to cache a portion of the most recent data, and Disabled to avoid caching undisplayed data.

Limit data points to

The number of data points the block caches, using the most recent data. You see this field only if you set Store data when scope is closed to Limited.

Statistics Tab

These parameters determine whether the block produces data at signal output ports or omits those ports. For descriptions of the data and ports, see the preceding table, "Signal Output Ports".

Number of points plotted, #c

Allows you to use the signal output port labeled #c.

Examples

The model below (open modelmodel) shows the relationship between the utilization of a server and the interarrival time of entities.